§ 4.2.15. Requirements for all commercial and industrial zoning classifications.  


Latest version.
  • A.

    Within commercially zoned districts, unless otherwise noted the listed uses shall mean the sale of finished products or units.

    B.

    No structure may be erected, placed upon or extend over any easement unless approved in writing by the person or entity holding said easement.

    C.

    All security residences or residential units must be of similar construction and architectural style as the primary structure.

    D.

    All security or residential units must be to the side or rear of the primary structure and location shall be approved administratively.

    E.

    Ground and building lights shall be confined to the property and shall not cast direct light on adjacent properties. The maximum height of a light pole shall be 35 feet in all commercial zoning classifications except B-1 and RAC where the maximum height is 25 feet.

    F.

    For all other outdoor lighting requirements, refer to Sec. 6.19.6.

    G.

    Trash containers shall be screened from public view, using opaque materials.

    H.

    All setbacks shall be measured from the outside wall of buildings or structures and from the concrete curb surrounding gas pumps; however, eaves, roof overhangs or pilasters may protrude two feet into a required setback. Gas pump island canopies may protrude ten feet into a required setback.

    I.

    Screening of Activities. Areas used for parking of commercial vehicles, or storage of vehicles, or outdoor storage or uses shall be screened, buffered or fenced in such a manner as to screen said areas from view from access streets, freeways and incompatible adjacent properties. Such screening shall form a complete opaque screen up to a point eight feet in vertical height.

(Ord. No. 17-08, § 2(Exh. A), 4-11-2017)